Documentation

5.4. Frequency-Band Graphs

Updated 31 August 20261 min read

On the left side of the interface, power graphs for the four EEG channels (F7, AF3, AF4, F8) are displayed for all sections.

Power Domain frequency-band graphs showing stacked power spectra for the four EEG channels F7, AF3, AF4 and F8, each overlaid with curves for multiple recording sections, with Trim, CAR, Denoise, log-scale and decomposition-method controls at top.

Method:

  • FFT is computed for each section.
  • A power spectrum is constructed:
    P = abs(FFT(signal)) / length(signal)
  • Smoothing is applied.
  • The spectrum from 0 to 100 Hz is displayed.

Colors: each section has its own color for visual distinction.